Exergetic Performance of Household Refrigerator using R600a and LPG

11Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This paper presents a case study of coefficient of performance (COP), exergetic performance and irreversibility of four major components (compressor, condenser, capillary tube and evaporator) of a household refrigerator using R600a and LPG. The results showed that the COP and exergetic efficiency of LPG were 9.5% and 7.1% higher than that of R600a respectively. Also, the total irreversibility of LPG was lower than that of R600a with 22.4%. In general, LPG performed better than R600a in terms of COP, power consumption, exergetic efficiency and irreversibility in the system.

Author supplied keywords

Cite

CITATION STYLE

APA

Babarinde, T. O., Akinlabi, S. A., & Madyira, D. M. (2018). Exergetic Performance of Household Refrigerator using R600a and LPG. In IOP Conference Series: Materials Science and Engineering (Vol. 413). Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/413/1/012069