Radiation induced degradation of rhodamine 6G and 7-Diethylamino-4-methylcoumarin in nano-clay gel for use in dosimeter

7Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Rhodamine 6G (R6G) and 7-diethylamino-4-methylcoumarin (7D4MC) were applied to a nanoclay gel dosimeter based on radiation-induced degradation. The radiological properties were evaluated under X-ray irradiation. The fluorescent dyes showed linear degradation with an increase in dose. In addition, the distribution of fluorescence induced by inhomogeneous irradiation was maintained for two months and a suppressed diffusion of the fluorescent dyes in the gel matrix was observed.

Cite

CITATION STYLE

APA

Maeyama, T., Mochizuki, A., & Takanashi, T. (2019). Radiation induced degradation of rhodamine 6G and 7-Diethylamino-4-methylcoumarin in nano-clay gel for use in dosimeter. In Journal of Physics: Conference Series (Vol. 1305). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/1305/1/012045