Design and Implementation of an ARM-Based AI Module for Ectopic Beat Classification Using Custom and Structural Pruned Lightweight CNN

6Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This article presents the development and testing of lightweight and power-efficient CNN models for ectopic beat classification, tailored for a compact-sized (25× 45 mm) ARM-based (STM32H7) AI module. Two custom lightweight architectures (LMUEBCNet and SEmbedNet) were introduced, and their performances benchmarked against conventional models (AlexNet and VGG19). A structural pruning method, filter pruning via the Taylor score, was employed for pretrained models' parameter optimizations. Further resizing the input image size to pixel-56/112 for the efficiency of the embedded system. Validation was conducted utilizing a combined electrocardiogram (ECG) simulator and the PhysioNet Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia ECG dataset, adhering to the ANSI/Association for the Advancement of Medical Instrumentation (AAMI) EC57 standard. SEmbedNet with parameter size of 0.04 M and LMUEBCNet with 0.15 M parameters reported accuracy of 99.9%/97.6%. In comparison, the pruned models of VGG19 and AlexNet, which had parameter counts of 0.10 and 0.07 M, respectively, achieved accuracy of 96.7%/94.4%. Poststructural pruning, VGG19 and AlexNet models, saw reductions in parameters by thousands of times, with accuracy decreases of 2% to 5%. Notably, the proposed LMUEBCNet and SEmbedNet were vastly leaner by 930 and 320 times than VGG19 and AlexNet. The proposed ARM-based AI module integrated with custom lightweight CNN models offers superior accuracy-memory trade-offs with 0.04 M parameters, which is less than 1% of the size of conventional models. The AI module with compact size and a power consumption of only 0.4 W achieves a classification rate of 4.2 segments per second and 99.9% accuracy. The AI module shows the potential to transform ECG monitoring devices into ECG analyzers.

Cite

CITATION STYLE

APA

Xie, Y. L., Lin, X. R., Lee, C. Y., & Lin, C. W. (2024). Design and Implementation of an ARM-Based AI Module for Ectopic Beat Classification Using Custom and Structural Pruned Lightweight CNN. IEEE Sensors Journal, 24(12), 19834–19844. https://doi.org/10.1109/JSEN.2024.3393469

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free