Abstract
The accurate detection and typing of high-risk human papillomavirus (HPV) are critical for cervical cancer screening. The Hybrid Capture 2 (hc2) and cobas HPV tests showed high agreement for cervical samples (94.4%,κ=0.72, n=693) and moderate agreement for vaginal samples (κ=0.62, n=108). The HPV16 and HPV18 results were highly consistent between the cobas and Linear Array tests (κ≥0.96, n=197). Three hc2-negative vaginal samples were repeatedly invalid by the cobas test due to β-globin control failures, highlighting amplification control benefits. No cross-contamination was detected in a challenge experiment. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Cite
CITATION STYLE
Pyne, M. T., Law, C., Hillyard, D. R., & Schlaberg, R. (2014). Testing and genotyping of high-risk human papillomavirus by the cobas HPV test and the Hybrid Capture 2 high-risk HPV dna test using cervical and vaginal samples. Journal of Clinical Microbiology, 52(5), 1720–1723. https://doi.org/10.1128/JCM.03308-13