Performance characteristic of endoscopic ultrasound-guided fine needle aspiration is unaffected by pancreatic mass size

  • Ramesh J
  • Kim H
  • Reddy K
  • et al.
N/ACitations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

BACKGROUND AND STUDY AIMS: Despite a well-established tool for diagnosis of pancreatic masses, endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) studies have shown suboptimal diagnostic performance at divergent mass sizes. Since the impact of gold standard follow-up and presence of on-site evaluation on this observation is unknown, we aimed to study the performance characteristics of EUS-FNA under these strict conditions. PATIENTS AND METHODS: EUS-FNA results from pancreatic mass lesions performed between July 2000 and March 2013 were evaluated. All patients with histological follow-up were then stratified into four groups: Group A ( ≤ 10 mm), Group B (11 - 20 mm), Group C (21 - 40 mm), and Group D (> 40 mm). Sensitivity and diagnostic accuracy were calculated for each group and compared. RESULTS: A total of 612 /3832 (16 %) patients with pancreatic masses who underwent EUS-FNA had histology confirmation. Of these, 81 were excluded due to unavailable lesion size, while the rest formed the study cohort. Mean age (SD) was 65.8 years (9.3) with 51.2 % female. The mean number of passes for the entire cohort was 2.9 (SD 1.9; range 1 - 12); patients in group D had a significantly higher number of passes for on-site diagnosis (P = 0.0124). There was no significant difference between the groups for sensitivity (P = 0.1134) or diagnostic accuracy (P = 0.2111). Proportional trend analysis revealed no significant correlation between size and sensitivity (P = 0.6192). The size of lesion measured by EUS was not associated with sensitivity or specificity after adjusting for age, sex, and pancreatic location. CONCLUSION: In the presence of rapid on-site cytopathology and when final histology is taken as the gold standard, pancreatic mass size does not affect the performance characteristics of EUS-FNA.

Cite

CITATION STYLE

APA

Ramesh, J., Kim, H., Reddy, K., & Eltoum, I.-E. (2016). Performance characteristic of endoscopic ultrasound-guided fine needle aspiration is unaffected by pancreatic mass size. Endoscopy International Open, 04(04), E434–E438. https://doi.org/10.1055/s-0035-1569969

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free