Assessment of normal hemodynamic profile of mechanical pulmonary prosthesis by doppler echocardiography: a prospective cross-sectional study

3Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVES: Very few reports have described the Doppler-derived echocardiographic parameters for mechanical pulmonary valve prosthesis (MPVP). This study aims to describe the normal Doppler hemodynamic profile of MPVP using Doppler echocardiography. METHODS: The current prospective, single center observational study enrolled 108 patients who underwent pulmonary valve replacement (PVR) surgery for the first time and had a normally functioning prosthesis post-operation. The hemodynamic performance of MPVPs, considering flow dependent and flow independent parameters, was evaluated at two follow-up points, at week one and week four post-operation. All assessments were conducted by an experienced echocardiographer. RESULTS: The mean age (±SD) of the participants was 26.4 (±8.98). Tetralogy of Fallot (ToF) was the most common underlying disease leading to PVR, with a prevalence of 88%. At first week post-operation, measurement of indices reported the following values (±SD): peak pressure gradient (PPG): 18.51(±7.64) mm Hg; mean pressure gradient (MPG): 10.88(±5.62) mm Hg; peak velocity (PV): 1.97(±0.43)m/s; doppler velocity index (DVI): 0.61(±18); pulmonary velocity acceleration time (PVAT): 87.35(±15.16) ms; effective orifice area (EOA): 2.98(±1.02) cm2;and effective orifice area to body surface area ratio (EOA/ BSA): 1.81(±0.62) cm2/m2. Comparing these measurements with those obtained from the second follow-up (at week four post-op) failed to hold significant difference in all values except for PVAT, which had increased from its primary value (p = 0.038). Also, right ventricular (RV) function showed significant improvement throughout the follow up period. CONCLUSION: The findings of this study help strengthen the previously scarce data pool and better establish the normal values for Doppler hemodynamics in mechanical pulmonary prosthesis.

Cite

CITATION STYLE

APA

Shojaeifard, M., Daryanavard, A., Karimi Behnagh, A., Moradian, M., Erami, S., & Dehghani Mohammad Abadi, H. (2020). Assessment of normal hemodynamic profile of mechanical pulmonary prosthesis by doppler echocardiography: a prospective cross-sectional study. Cardiovascular Ultrasound, 18(1), 14. https://doi.org/10.1186/s12947-020-00196-0

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free