Calibration of electret-based integral radon monitors using NIST polyethylene-encapsulated 226Ra/222Rn emanation (PERE) standards

  • Colle R
  • Kotrappa P
  • Hutchinson J
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

The recently developed 222 Rn emanation standards that are based on polyethylene-encapsulated 226 Ra solutions were employed for a first field-measurement application test to demonstrate their efficacy in calibrating passive integral radon monitors. The performance of the capsules was evaluated with respect to the calibration needs of electret ionization chambers (E-PERM ® , Rad Elec Inc.). The encapsulated standards emanate well-characterized and known quantities of 222 Rn, and were used in two different-sized, relatively-small, accumulation vessels (about 3.6 L and 10 L) which also contained the deployed elec-tret monitors under test. Calculated integral 222 Rn activities from the capsules over various accumulation times were compared to the averaged electret responses. Evaluations were made with four encapsulated standards ranging in 226 Ra activity from approximately 15 Bq to 540 Bq (with 222 Rn emanation fractions of 0.888); over accumulation times from 1 d to 33 d; and with four different types of E-PERM detectors that were independently calibrated. The ratio of the electret chamber response ERn to the integral 222 Rn activity IRn was constant (within statistical variations) over the variables of the specific capsule used, the accumulation volume, accumulation time, and detector type. The results clearly demonstrated the practicality and suitability of the encapsulated standards for providing a simple and readily-available calibration for those measurement applications. However, the mean ratio ERn/IRn was approximately 0.91, suggesting a possible systematic bias in the extant E-PERM calibrations. This 9 % systematic difference was verified by an independent test of the E-PERM calibration based on measurements with the NIST ra-don-in-water standard generator.

Cite

CITATION STYLE

APA

Colle, R., Kotrappa, P., & Hutchinson, J. M. R. (1995). Calibration of electret-based integral radon monitors using NIST polyethylene-encapsulated 226Ra/222Rn emanation (PERE) standards. Journal of Research of the National Institute of Standards and Technology, 100(6), 629. https://doi.org/10.6028/jres.100.047

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free