Repeatability of quantitative FDG-PET/CT and contrast- Enhanced CT in recurrent ovarian carcinoma: Test-Retest measurements for TumorFDGUptake, diameter, and volume

37Citations
Citations of this article
40Readers
Mendeley users who have this article in their library.

Abstract

Purpose: Repeatability of baseline FDG-PET/CT measurements has not been tested in ovarian cancer. This dual-center, prospective study assessed variation in tumor 2[18F]fluoro-2-deoxy-D-glucose (FDG) uptake, tumor diameter, and tumor volume from sequential FDG-PET/CT and contrast-enhanced computed tomography (CECT) in patients with recurrent platinum-sensitive ovarian cancer. Experimental Design: Patients underwent two pretreatment baseline FDG-PET/CT (n = 21) and CECT (n = 20) at two clinical sites with different PET/CT instruments. Patients were included if they had at least one target lesion in the abdomen with a standardized uptake value (SUV) maximum (SUVmax) of2.5 and a long axis diameter of 15 mm. Two independent reading methods were used to evaluate repeatability of tumor diameter and SUV uptake: on site and at an imaging clinical research organization (CRO). Tumor volume reads were only performed by CRO. In each reading set, target lesions were independently measured on sequential imaging. Results: Median time between FDG-PET/CT was two days (range 1-7). For site reads, concordance correlation coefficients (CCC) for SUVmean, SUVmax, and tumor diameter were 0.95, 0.94, and 0.99, respectively. Repeatability coefficients were 16.3%, 17.3%, and 8.8% for SUVmean, SUVmax, and tumor diameter, respectively. Similar results were observed for CRO reads. Tumor volume CCC was 0.99 with a repeatability coefficient of 28.1%. Conclusions: There was excellent test-retest repeatability for FDG-PET/CT quantitative measurements across two sites and two independent reading methods. Cutoff values for determining change in SUVmean, SUVmax, and tumor volume establish limits to determine metabolic and/or volumetric response to treatment in platinum-sensitive relapsed ovarian cancer. Clin Cancer Res ©2014 American Association for Cancer Research.

Cite

CITATION STYLE

APA

Rockall, A. G., Avril, N., Lam, R., Iannone, R., Mozley, P. D., Parkinson, C., … Brenton, J. D. (2014). Repeatability of quantitative FDG-PET/CT and contrast- Enhanced CT in recurrent ovarian carcinoma: Test-Retest measurements for TumorFDGUptake, diameter, and volume. Clinical Cancer Research, 20(10), 2751–2760. https://doi.org/10.1158/1078-0432.CCR-13-2634

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free