Hand-Held Tidal Breathing Nasal Nitric Oxide Measurement - A Promising Targeted Case-Finding Tool for the Diagnosis of Primary Ciliary Dyskinesia

55Citations
Citations of this article
56Readers
Mendeley users who have this article in their library.

Abstract

Background: Nasal nitric oxide (nNO) measurement is an established first line test in the work-up for primary ciliary dyskinesia (PCD). Tidal breathing nNO (TB-nNO) measurements require minimal cooperation and are potentially useful even in young children. Hand-held NO devices are becoming increasingly widespread for asthma management. Therefore, we chose to assess whether hand-held TB-nNO measurements reliably discriminate between PCD, and Healthy Subjects (HS) and included Cystic Fibrosis (CF) patients as a disease control group known to have intermediate nNO levels. Methods: In this cross sectional, single centre, single occasion, proof-of-concept study in children and adults with PCD and CF, and in HS we compared feasibility, success rates, discriminatory capacity, repeatability and agreement between a hand-held electrochemical device equipped with a nNO software application sampling at flow rates 2 ml/s or 5 ml/s, and two stationary chemiluminescence devices, applying both tidal breathing and velum closure techniques. Results: Measurements were done in 16 PCD patients, 21 patients with CF and 20 HS aged between 3.8 and 60.9 years. Hand-held TB-nNO showed high success rate (96.5-100%) vs. velum closure nNO techniques (70.2-89.5%). Hand-held TB-nNO sampling at flow rate 5 ml/s showed equally high discriminative power (PCD vs. HS [p<0.0001] and PCD vs. CF [p<0.0001]) and reaching close to 100% sensitivity and specificity, superior repeatability (CV% = 10%) and equal limits of agreement compared to TB-nNO by stationary devices and even compared to velum closure sampling. Conclusion: Hand-held TB-nNO discriminates significantly between PCD, CF and HS and shows promising potential as a widespread targeted case-finding tool for PCD, although further studies are warranted before implementation. © 2013 Marthin and Nielsen.

Cite

CITATION STYLE

APA

Marthin, J. K., & Nielsen, K. G. (2013). Hand-Held Tidal Breathing Nasal Nitric Oxide Measurement - A Promising Targeted Case-Finding Tool for the Diagnosis of Primary Ciliary Dyskinesia. PLoS ONE, 8(2). https://doi.org/10.1371/journal.pone.0057262

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free