New solution for the high accuracy alignment of accelerator components

14Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

Several state-of-the-art metrology measurement methods have been investigated and combined for a fiducialization of accelerator components in the micrometric regime. The PACMAN project at CERN applied stretched-wire measurement methods to Compact Linear Collider quadrupole and cavity beam position monitor prototypes, to locate their magnetic, respectively, electromagnetic, axis using a dedicated test stand and to determine the position of the wire with respect to external alignment targets (fiducials) testing different methods, such as coordinate measuring machine measurements and microtriangulation. Further studies have been performed using a nanopositioning system, verifying the absolute accuracy and repeatability of the fiducialization method within a few micrometers.

Cite

CITATION STYLE

APA

Caiazza, D., Catalan Lasheras, N., Mainaud Durand, H., Modena, M., Sanz, C., Tshilumba, D., … Zorzetti, S. (2017). New solution for the high accuracy alignment of accelerator components. Physical Review Accelerators and Beams, 20(8). https://doi.org/10.1103/PhysRevAccelBeams.20.083501

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley