A feasibility study of a handmade ultrasound-guided phantom for paracentesis

0Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Simulation-based training is effective for ultrasound (US)-guided procedures. However, commercially developed simulators are costly. This study aims to evaluate the feasibility of a hand-made phantom for US-guided paracentesis. Methods: We described the recipe to prepare an agar phantom. We collected the US performance data of 50 novices, including 22 postgraduate-year (PGY) residents and 28 undergraduate-year (UGY) students, who used the phantom for training, as well as 12 emergency residents with prior US-guided experience. We obtained the feedback after using the phantom with the Likert 5-point scale. The data were presented with medians and interquartile ranges (IQRs) and analyzed by the Wilcoxon rank sum test. Results: While emergency residents demonstrated superior performance compared to trainees, all trainees exhibited acceptable proficiency (global rating of ≥ 3, 50/50 vs. 12/12, p = 1.000) and comparable needle steadiness [5 (5) vs. 5 (5), p = 0.223]. No significant difference in performance was observed between PGYs [5 (4–5)] and UGYs [5 (4–5), p = 0.825]. No significant differences were observed in terms of image stimulation, puncture texture, needle visualization, drainage simulation, and endurance of the phantom between emergency residents and trainees. However, experienced residents rated puncture texture and draining fluid as “neutral” (3/5 on the Likert scale). The cost of the paracentesis phantom is US$16.00 for at least 30 simulations, reducing it to US$6.00 without a container. Conclusions: The paracentesis phantom proves to be a practical and cost-effective training tool. It enables novices to acquire paracentesis skills, enhances their US proficiency, and boosts their confidence. Nevertheless, further investigation is needed to assess its long-term impact on clinical performance in real patients. Trial registration: NCT04792203 at the ClinicalTrials.gov.

Cite

CITATION STYLE

APA

Huang, C. T., Lin, C. H., Lin, S. Y., Huang, S., & Lien, W. C. (2024). A feasibility study of a handmade ultrasound-guided phantom for paracentesis. BMC Medical Education, 24(1). https://doi.org/10.1186/s12909-024-05339-9

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free