Aims Transcatheter aortic valve implantation (TAVI) has developed from a procedure for patients with aortic stenosis inoperable or high risk for surgery, into a treatment option even for intermediate risk elderly patients. This development has been facilitated by the clinical learning curve and constant improvements of transcatheter heart valves used. We present total 1-year results of SOURCE 3, the European post-approval multicentre registry of the latest generation balloon expandable SAPIEN 3TM (Edwards Lifesciences, Irvine, CA, USA). Methods and results Participating centres have submitted their consecutive experience with the SAPIEN 3, dependent on patients consent. Data were prospectively collected and all end point-related outcomes adjudicated according to VARC-2 definitions by an independent committee. Between July 2014 and October 2015, in total 1946 patients (mean age 81.6 ± 6.7 years, 52% male) were enrolled in 80 centres from 10 European countries. At 1 year, all-cause mortality was 12.6%, cardiovascular mortality 8.0%, stroke 3.1%, disabling stroke 1.4%, and rate of new pacemakers 13.2%. Causes of death were 62.0% cardiovascular and 38.0% non-cardiovascular, with heart failure (13.4%) and pulmonary complications (12.7%) being the main reasons for fatal outcomes. Multivariable analysis identified New York Heart Association Class IV and renal insufficiency as predictors of mortality, while higher BMI's improved survival. Severe (zero) and moderate paravalvular leakage (2.6%) was rare at 1 year. Conclusion In SOURCE 3, we observe a low complication rate and mortality at 1 year. Given the low incidence of higher degree paravalvular leakages, this variable did no longer affect outcome.

Cite

CITATION STYLE

APA

Wendler, O., Schymik, G., Treede, H., Baumgartner, H., Dumonteil, N., Neumann, F. J., … Vahanian, A. (2017). SOURCE 3: 1-year outcomes post-transcatheter aortic valve implantation using the latest generation of the balloon-expandable transcatheter heart valve. European Heart Journal, 38(36), 2717–2726. https://doi.org/10.1093/eurheartj/ehx294

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free