Comparison of the efficacy and safety of MAKO robot-assisted total knee arthroplasty versus conventional manual total knee arthroplasty in uncomplicated unilateral total knee arthroplasty a single-centre retrospective analysis

36Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To compare the efficacy and safety of MAKO robot-assisted total knee arthroplasty (MA-TKA) with conventional manual total knee arthroplasty (CM-TKA) in patients with end-stage knee osteoarthritis (KOA) during the early postoperative period. Method: A retrospective analysis was conducted on 22 patients with KOA who underwent MA-TKA and 26 patients who underwent CM-TKA from April 2023 to July 2023. Hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), American Knee Society Score (AKSS), Forgotten Joint Score-12 (FJS-12), visual analogue scale (VAS), and postoperative complications were recorded and compared between the two groups. Result: Both groups successfully completed the surgeries. In terms of radiographic parameters, postoperative one month LDFA and HKA in the MA-TKA group were significantly lower than those in the CM-TKA group (P < 0.05). At the one month follow-up, 19 patients (86.4%) in the MA-TKA group had an HKA less than 3°, compared to 20 patients (76.9%) in the CM-TKA group. Clinically, VAS scores at 24 h, 48 h, and 72 h postoperatively were lower in the MA-TKA group both at rest and during activity. At one month and three months postoperatively, AKSS Function Scores and FJS-12 scores in the MA-TKA group were significantly higher than those in the CM-TKA group (P < 0.05). Regarding postoperative complications, no complications occurred in the MA-TKA group, while one patient in the CM-TKA group experienced postoperative knee stiffness, which resolved after physical therapy, with no statistically significant difference (P > 0.05). Conclusion: Compared with conventional manual total knee arthroplasty, MAKO robot-assisted TKA demonstrates better short-term clinical efficacy, achieves better alignment planning, and maintains good safety.

Cite

CITATION STYLE

APA

Ma, N., Sun, P., Xin, P., Zhong, S., Xie, J., & Xiao, L. (2024). Comparison of the efficacy and safety of MAKO robot-assisted total knee arthroplasty versus conventional manual total knee arthroplasty in uncomplicated unilateral total knee arthroplasty a single-centre retrospective analysis. International Orthopaedics, 48(9), 2351–2358. https://doi.org/10.1007/s00264-024-06234-0

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free