Automated titanium fastener for surgical aortic valve replacement—preventive role for infective endocarditis?

6Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

OBJECTIVES: Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain. METHODS: A total of 1405 patients who underwent surgical aortic valve replacement between January 2016 and December 2022 were included and grouped according to the suture-securing technique used (automated titanium fastener versus hand-tied knots). The occurrence of infective endocarditis during follow-up was set as the primary study end-point. As secondary study end-points, stroke, all-cause mortality and a composite outcome of either infective endocarditis, stroke, or all-cause mortality were assessed. RESULTS: The automated titanium fastener was used in 829 (59%) patients, whereas the hand-knot tying technique was used in 576 (41%) patients. The multivariable proportional competing risk regression analysis showed a significantly lower risk of infective endocarditis during follow-up in the automated titanium fastener group (adjusted sub-hazard ratio 0.44, 95% confidence interval 0.20–0.94, P ¼ 0.035). The automated titanium fastener group was not associated with an increased risk of mortality or attaining the composite outcome, respectively (adjusted hazard ratio 0.81, 95% confidence interval 0.60–1.09, P ¼ 0.169; adjusted hazard ratio 0.82, 95% confidence interval 0.63–1.07, P ¼ 0.152). This group was not associated with an increased risk of stroke (adjusted sub-hazard ratio 0.82, 95% confidence interval 0.47–1.45, P ¼ 0.504). Also, a significantly lower rate of early-onset infective endocarditis was observed in the automated titanium fastener group, (0.4% vs 1.4%, P ¼ 0.032). CONCLUSIONS: Suture-securing with an automated titanium fastener device appears to be superior compared to the hand-knot tying technique in terms of lower risk of infective endocarditis.

Cite

CITATION STYLE

APA

Kahrovic, A., Herkner, H., Angleitner, P., Werner, P., Kocher, A., Ehrlich, M., … Andreas, M. (2024). Automated titanium fastener for surgical aortic valve replacement—preventive role for infective endocarditis? European Journal of Cardio-Thoracic Surgery , 65(6). https://doi.org/10.1093/ejcts/ezae236

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free