Comparative review of algorithms and methods for chemical-shift-encoded quantitative fat-water imaging

13Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To propose a standardized comparison between state-of-the-art open-source fat-water separation algorithms for proton density fat fraction (PDFF) and (Formula presented.) quantification using an open-source multi-language toolbox. Methods: Eight recent open-source fat-water separation algorithms were compared in silico, in vitro, and in vivo. Multi-echo data were synthesized with varying fat-fractions, B0 off-resonance, SNR and TEs. Experimental evaluation was conducted using calibrated fat-water phantoms acquired at 3T and multi-site open-source phantoms data. Algorithms' performances were observed on challenging in vivo datasets at 3T. Finally, reconstruction algorithms were investigated with different fat spectra to evaluate the importance of the fat model. Results: In silico and in vitro results proved most algorithms to be not sensitive to fat-water swaps and (Formula presented.) offsets with five or more echoes. However, two methods remained inaccurate even with seven echoes and SNR = 50, and two other algorithms' precision depended on the echo spacing scheme (p < 0.05). The remaining four algorithms provided reliable performances with limits of agreement under 2% for PDFF and 6 s−1 for (Formula presented.). The choice of fat spectrum model influenced quantification of PDFF mildly (<2% bias) and of (Formula presented.) more severely, with errors up to 20 s−1. Conclusion: In promoting standardized comparisons of MRI-based fat and iron quantification using chemical-shift encoded multi-echo methods, this benchmark work has revealed some discrepancies between recent approaches for PDFF and (Formula presented.) mapping. Explicit choices and parameterization of the fat-water algorithm appear necessary for reproducibility. This open-source toolbox further enables the user to optimize acquisition parameters by predicting algorithms' margins of errors.

Cite

CITATION STYLE

APA

Daudé, P., Roussel, T., Troalen, T., Viout, P., Hernando, D., Guye, M., … Rapacchi, S. (2024). Comparative review of algorithms and methods for chemical-shift-encoded quantitative fat-water imaging. Magnetic Resonance in Medicine, 91(2), 741–759. https://doi.org/10.1002/mrm.29860

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free