Determinação rápida de hidroquinona usando aná:lise por injeção em batelada (bia) com detecção amperométrica

11Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

A fast analytical method for determination of hydroquinone in pharmaceutical formulations employing batch injection analysis (BIA) with amperometric detection using a boron-doped diamond electrode is described. The supporting electrolyte was a 0.1 mol L-1 H2SO4 solution (the single reagent used for analysis). The method showed good repeatability (RSD of 0.45%, n=20), wide linear range (from 10 to 2000 μmol L-1, R=0.9999), low detection limit (0.016 μmol L-1) and satisfactory recovery values (91-96%). Accuracy of the method was evaluated by comparative analyses using high-performance liquid-chromatography. The ability to replace the electronic pipette by disposable syringes (injection procedure) in BIA systems was also shown.

Cite

CITATION STYLE

APA

Cunha, R. R., Tormin, T. F., Richter, E. M., & Munoz, R. A. A. (2013). Determinação rápida de hidroquinona usando aná:lise por injeção em batelada (bia) com detecção amperométrica. Quimica Nova, 36(5), 663–668. https://doi.org/10.1590/S0100-40422013000500009

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free