Abstract
Computer simulations of stable xenon ((S)Xe) uptake curves were used to evaluate the effect of xenon-induced flow activation on CBF calculations by xenon-enhanced computed tomography. Estimates of flow activation were based on repeated transcranial Doppler measurements of blood velocity during 4.5 minutes of (S)Xe inhalation. The synthetic curves were generated from a generalized Kety equation that included time-varying blood flow activation. In contrast to the peak 35% increase in blood flow velocity during (S)Xe inhalation, a standard analysis of the flow-varying synthetic curves revealed only minor 3% to 5% increases in calculated CBF. It is concluded that brief xenon inhalations can provide blood flow estimates that contain minimal bias from activation.
Author supplied keywords
Cite
CITATION STYLE
Obrist, W. D., Zhang, Z., & Yonas, H. (1998). Effect of xenon-induced flow activation on xenon-enhanced computed tomography cerebral blood flow calculations. Journal of Cerebral Blood Flow and Metabolism, 18(11), 1192–1195. https://doi.org/10.1097/00004647-199811000-00005