99mTc-mebrofenin hepatobiliary scintigraphy and volume metrics before liver preparation: correlations and discrepancies in non-cirrhotic patients

  • Guiu B
  • Deshayes E
  • Panaro F
  • et al.
N/ACitations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND: Accurate identification of insufficient future liver remnant (FLR) is required to select patients for liver preparation and limit the risk of post-hepatectomy liver failure (PHLF). The objective of this study was to investigate the correlations and discrepancies between the most-commonly used FLR volume metrics and (99m)Tc-mebrofenin hepatobiliary scintigraphy (HBS). METHODS: In 101 non-cirrhotic patients who underwent HBS before major hepatectomy, we retrospectively analyzed the correlations and discrepancies between FLR function and FLR volume metrics: actual percentage (FLRV%), standardized to body surface area (FLRV%(BSA)) and weight (FLRV%(weight)), and FLR to body weight ratio (FLRV-BWR). RESULTS: Among 67 patients with FLR function ≥2.69%/min/m(2), PHLF was observed in none and 13 patients according to respectively 50-50 and ISGLS criteria. FLRV%, FLRV%(BSA), FLRV%(weight) and FLRV-BWR significantly correlated with FLR function (P<0.001), with Spearman's correlation coefficients of 0.680, 0.704, 0.698, and 0.711, respectively. No difference was observed between the areas under the curve of FLRV%, FLRV%(BSA), FLRV%(weight) and FLR-BWR (all P=ns). Overall, the percentages of patients misclassified by FLRV%, FLRV%(BSA), FLRV%(weight) (thresholds: 30%) and FLR-BWR (threshold: 0.5) versus FLR function (threshold: 2.69%/min/m(2)) were 23.8% (95% CI: 15.9-33.3%), 18.8% (95% CI: 11.7-27.8%), 17.8% (95% CI: 11-26.7%), and 31.7% (95% CI: 22.8-41.7%), respectively. FLR volume metrics wrongly classified 1-13.9% of patients with sufficient FLR function (i.e., ≥2.69%/min/m(2)), and 9.9-30.7% of patients with insufficient FLR function. FLRV-BWR was the most and the least reliable measure to identify patients with sufficient and insufficient FLR function, respectively. CONCLUSIONS: Despite significant correlations, the discrepancy rates between FLR volume and function metrics speaks in favor of implementing (99m)Tc-mebrofenin HBS in the work-up before liver preparation.

Cite

CITATION STYLE

APA

Guiu, B., Deshayes, E., Panaro, F., Sanglier, F., Cusumano, C., Herrerro, A., … Cassinotto, C. (2021). 99mTc-mebrofenin hepatobiliary scintigraphy and volume metrics before liver preparation: correlations and discrepancies in non-cirrhotic patients. Annals of Translational Medicine, 9(9), 795–795. https://doi.org/10.21037/atm-20-7372

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free