Effect of cold-rolled thickness reduction degree on characteristics of hydrogen diffusion in silicon steel

3Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The characteristic of hydrogen uptake and diffusion in the cold-rolled silicon steel was investigated by electrochemical hydrogen permeation technique performed under different cathodic charging current density and cold-rolled thickness reduction degree. The results indicated that anodic permeation current density increased with increasing cathodic charging current for the specimens. Moreover, the anodic steady state permeation current density and the solubility increased with an increase in the cold-rolled thickness reduction degrees. The breakthrough time of hydrogen in the specimens was shortened with increasing thickness reduction degrees, and the value of the hydrogen diffusivity decreased gradually with increasing thickness reduction degrees. © 2014 Yongfeng Li et al.

Cite

CITATION STYLE

APA

Li, Y., Cai, L., Liu, G., & Ma, L. (2014). Effect of cold-rolled thickness reduction degree on characteristics of hydrogen diffusion in silicon steel. International Journal of Corrosion, 2014. https://doi.org/10.1155/2014/309416