Abstract
A suboptimal control strategy to control heat treatment processes in a direct-fired batch type furnace is formulated. It minimizes deviations from a prescribed temporal load temperature profile and the energy input in terms of the fuel consumption. The control method requires a model for the heat transfer and combustion, which is described. Application of the method shows that the fuel input and heat transfer to the load can be controlled to maintain a specified instantaneous temperature. This is accomplished through a feedback loop that is constructed by comparing the desired and measured temperatures. A parametric study is conducted to demonstrate the model. © 2004 Elsevier Ltd. All rights reserved.
Author supplied keywords
Cite
CITATION STYLE
Banerjee, S., Sanyal, D., Sen, S., & Puri, I. K. (2004). A methodology to control direct-fired furnaces. International Journal of Heat and Mass Transfer, 47(24), 5247–5256. https://doi.org/10.1016/j.ijheatmasstransfer.2004.06.023