Association of Sit-to-Stand Capacity and Free-Living Performance Using Thigh-Worn Accelerometers among 60- to 90-Yr-Old Adults

7Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose Five times sit-to-stand (STS) test is commonly used as a clinical assessment of lower-extremity functional ability, but its association with free-living performance has not been studied. Therefore, we investigated the association between laboratory-based STS capacity and free-living STS performance using accelerometry. The results were stratified according to age and functional ability groups. Methods This cross-sectional study included 497 participants (63% women) 60-90 yr old from three independent studies. A thigh-worn triaxial accelerometer was used to estimate angular velocity in maximal laboratory-based STS capacity and in free-living STS transitions over 3-7 d of continuous monitoring. Functional ability was assessed with short physical performance battery. Results Laboratory-based STS capacity was moderately associated with the free-living mean and maximal STS performance (r = 0.52-0.65, P < 0.01). Angular velocity was lower in older compared with younger and in low- versus high-functioning groups, in both capacity and free-living STS variables (all P < 0.05). Overall, angular velocity was higher in capacity compared with free-living STS performance. The STS reserve (test capacity - free-living maximal performance) was larger in younger and in high-functioning groups compared with older and low-functioning groups (all P < 0.05). Conclusions Laboratory-based STS capacity and free-living performance were found to be associated. However, capacity and performance are not interchangeable but rather provide complementary information. Older and low-functioning individuals seemed to perform free-living STS movements at a higher percentage of their maximal capacity compared with younger and high-functioning individuals. Therefore, we postulate that low capacity may limit free-living performance.

Cite

CITATION STYLE

APA

Löppönen, A., Delecluse, C., Suorsa, K., Karavirta, L., Leskinen, T., Meulemans, L., … Van Roie, E. (2023). Association of Sit-to-Stand Capacity and Free-Living Performance Using Thigh-Worn Accelerometers among 60- to 90-Yr-Old Adults. Medicine and Science in Sports and Exercise, 55(9), 1525–1532. https://doi.org/10.1249/MSS.0000000000003178

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free