Abstract
Traditional “gold standard” methods for quantifying arsenic (As) in rice are not ideal for routine analysis due to their time-consuming, expensive, and complex nature. Therefore, the aim of this study was to develop a simple, rapid, and minimally destructive method applying X-ray fluorescence (XRF) spectroscopy and chemometric modeling to quantify As in rice. Milled rice was spiked with As (63.47 – 553.43 μg kg−1), pelletized, and analyzed utilizing an energy-dispersive XRF spectrometer. The resultant spectra were used to generate a prediction model via partial least squares regression (PLSR), which showed strong predictive capabilities (R2 = 0.99, RMSEC = 14.3 μg kg−1) and strong sensitivity (LOD = 27.76 μg kg−1, LOQ = 92.52 μg kg−1). Validation was conducted using a certified reference material, yielding an error of prediction of only 8.96%. Analysis of rice and rice-based foods showed strong agreement between the current study and traditional methods, demonstrating its robust capabilities for routine analysis.
Author supplied keywords
Cite
CITATION STYLE
Carroll, M., Gao, Z., & He, L. (2026). Development of a Rapid, Minimally Destructive, and Accurate Method to Quantify Arsenic in Rice and Rice-Based Foods Utilizing X-ray Fluorescence Spectroscopy and Chemometrics. Food Analytical Methods, 19(2). https://doi.org/10.1007/s12161-025-02979-5