Abstract
Screen printed lead zirconate titanate (PZT) layers offer possibilities for both sensing and actuation applications. PZT materials are known to suffer a long-term ageing process that can affect their performance as functional materials. Measuring the rate of this ageing on thick-film piezoelectric materials is difficult due to the presence of a substrate, and suitable methods have not been reported in the literature. A technique for measuring the ageing rate of the d31 coefficient is described in this paper, and includes a composite test structure based on a steel substrate. The d31 coefficient is found to age at - 4.4% per time decade after polarization with no external stresses (for PZT-5H, a soft piezoelectric material). A method is also presented for measuring the ageing of the dielectric constant, K33, and this is found to have an ageing rate of - 1.34% per time decade. Techniques for exploring cyclical stress induced ageing of d31 are further described, and an interesting linear ageing characteristic is demonstrated.
Author supplied keywords
Cite
CITATION STYLE
Glynne-Jones, P., Beeby, S. P., & White, N. M. (2001). A method to determine the ageing rate of thick-film PZT layers. Measurement Science and Technology, 12(6), 663–670. https://doi.org/10.1088/0957-0233/12/6/302