Abstract
The use of continuous reactors for heterogeneous catalytic ozonation is yet to be investigated in order to develop a viable technology for industrial applications. This paper presents hydrodynamic and degradation studies on the use of a co-current down flow trickle bed reactor for heterogeneous catalytic ozonation of phenol (as model pollutant) over Fe-Diatomite pellets and Fe-coated glass beads. It was found that the reactor can operate under trickle or pulsing flow regimes, promoting mass transfer augmentation. Residence time distribution data, fitted with n-CSTR and axial dispersion (ADM) models, showed low axial dispersion and high flow distribution. Just the Fe-diatomite pellets showed important phenol adsorption (16 %). Degradation experiments demonstrated that phenol conversion was substantial when using both catalysts, up to 19,7 % pollutant conversion with liquid-phase space times of just 6 s. Compared to direct ozonation, the use of the Fe-diatomite pellets and Fe-coated glass beads enhanced the reactor performance by 48 % and 23 %, respectively. It was confirmed that mass transfer is an important factor that restricts this reaction system performance; consequently, further improvement in mass transport rate is necessary for system optimization.
Cite
CITATION STYLE
Briceño Mena, L., & Durán Herrera, E. (2020). Heterogeneous Catalytic Ozonation of Phenol over Iron-based Catalysts in a Trickle Bed Reactor. Revista Ingeniería, 30(2), 1–13. https://doi.org/10.15517/ri.v30i2.39236