Accuracy of invasive arterial pressure monitoring in cardiovascular patients: An observational study

47Citations
Citations of this article
111Readers
Mendeley users who have this article in their library.

This artice is free to access.

Abstract

Introduction: Critically ill patients and patients undergoing high-risk and major surgery, are instrumented with intra-arterial catheters and invasive blood pressure is considered the " gold standard" for arterial pressure monitoring. Nonetheless, artifacts due to inappropriate dynamic response of the fluid-filled monitoring systems may lead to clinically relevant differences between actual and displayed pressure values. We sought to analyze the incidence and causes of resonance/underdamping phenomena in patients undergoing major vascular and cardiac surgery. Methods: Arterial pressures were measured invasively and, according to the fast-flush Gardner's test, each patient was attributed to one of two groups depending on the presence (R-group) or absence (NR-group) of resonance/underdamping. Invasive pressure values were then compared with the non-invasive ones. Results: A total of 11,610 pulses and 1,200 non-invasive blood pressure measurements were analyzed in 300 patients. Ninety-two out of 300 (30.7%) underdamping/resonance arterial signals were found. In these cases (R-group) systolic invasive blood pressure (IBP) average overestimation of non-invasive blood pressure (NIBP) was 28.5 (15.9) mmHg (P <0.0001) while in the NR-group the overestimation was 4.1(5.3) mmHg (P <0.0001). The mean IBP-NIBP difference in diastolic pressure in the R-group was -2.2 (10.6) mmHg and, in the NR-group -1.1 (5.8) mmHg. The mean arterial pressure difference was 7.4 (11.2) mmHg in the R-group and 2.3 (6.4) mmHg in the NR-group. A multivariate logistic regression identified five parameters independently associated with underdamping/resonance: polydistrectual arteriopathy (P =0.0023; OR = 2.82), history of arterial hypertension (P =0.0214; OR = 2.09), chronic obstructive pulmonary disease (P =0.198; OR = 2.61), arterial catheter diameter (20 vs. 18 gauge) (P <0.0001; OR = 0.35) and sedation (P =0.0131; OR = 0.5). The ROC curve for the maximal pressure-time ratio, showed an optimum selected cut-off point of 1.67 mmHg/msec with a specificity of 97% (95% CI: 95.13 to 99.47%) and a sensitivity of 77% (95% CI: 67.25 to 85.28%) and an area under the ROC curve by extended trapezoidal rule of 0.88. Conclusion: Physicians should be aware of the possibility that IBP can be inaccurate in a consistent number of patients due to underdamping/resonance phenomena. NIBP measurement may help to confirm/exclude the presence of this artifact avoiding inappropriate treatments.

Cite

CITATION STYLE

APA

Romagnoli, S., Ricci, Z., Quattrone, D., Tofani, L., Tujjar, O., Villa, G., … De Gaudio, A. R. (2014). Accuracy of invasive arterial pressure monitoring in cardiovascular patients: An observational study. Critical Care, 18(6). https://doi.org/10.1186/s13054-014-0644-4

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free