Abstract
PURPOSE. To characterize the clinical profile of femtosecond lenticule extraction (FLEx) correlated with ultrastructural analysis of the corneal interface and in vivo real-time intraocular pressure (IOP). METHODS. Prospective clinical case series with experimental studies; consecutive patients underwent FLEx at a single tertiary center over 10 months with postsurgical follow-up of 3 months. The patients were divided into three groups according to spherical equivalence (SE) (A, < -5.0 diopters [D]; B, ≥ -5.00 D and < 0.001). Ultrastructurally, the smoothness of the corneal interface was independent of ablation depth (mean irregularity scores A, B, C: 8.8 ± 0.6, 10.3 ± 0.4, 8.7 ± 0.6, respectively; P = 0.88). The increase in IOP during FLEx was similar to that in femtosecond (FS)-LASIK, albeit a twofold duration of raised IOP in FLEx (P < 0.001). CONCLUSIONS. These results suggest that FLEx is predictable and effective in treating myopia and myopic astigmatism. Experimental studies support the early clinical results and safety of this procedure. © 2012 The Association for Research in Vision and Ophthalmology, Inc.
Cite
CITATION STYLE
Ang, M., Chaurasia, S. S., Angunawela, R. I., Poh, R., Riau, A., Tan, D., & Mehta, J. S. (2012). Femtosecond lenticule extraction (FLEx): Clinical results, interface evaluation, and intraocular pressure variation. Investigative Ophthalmology and Visual Science, 53(3), 1414–1421. https://doi.org/10.1167/iovs.11-8808