Thermometry of Red Blood Cell Concentrate: Magnetic Resonance Decoding Warm Up Process

3Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

Purpose: Temperature is a key measure in human red blood cell concentrate (RBC) quality control. A precise description of transient temperature distributions in RBC units removed from steady storage exposed to ambient temperature is at present unknown. Magnetic resonance thermometry was employed to visualize and analyse RBC warm up processes, to describe time courses of RBC mean, surface and core temperatures by an analytical model, and to determine and investigate corresponding model parameters. Methods: Warm-up processes of 47 RBC units stored at 1-6°C and exposed to 21.25°C ambient temperature were investigated by proton resonance frequency thermometry. Temperature distributions were visualized and analysed with dedicated software allowing derivation of RBC mean, surface and core temperature-time courses during warm up. Time-dependence of mean temperature was assumed to fulfil a lumped capacitive model of heat transfer. Time courses of relative surface and core temperature changes to ambient temperature were similarly assumed to follow shifted exponential decays characterized by a time constant and a relative time shift, respectively. Results: The lumped capacitive model of heat transfer and shifted exponential decays described time-dependence of mean, surface and core temperatures close to perfect (mean R2 were 0.999±0.001, 0.996±0.004 and 0.998±0.002, respectively). Mean time constants were τmean = 55.3±3.7 min, τsurface = 41.4±2.9 min and τcore = 76.8±7.1 min, mean relative time shifts were Δsurface = 0.07±0.02 and Δcore = 0.04±0.01. None of the constants correlated significantly with temperature differences between ambient and storage temperature. Conclusion: Lumped capacitive model of heat transfer and shifted exponential decays represent simple analytical formulas to describe transient mean, surface and core temperatures of RBC during warm up, which might be a helpful tool in RBC temperature monitoring and quality control. Independence of constants on differences between ambient and storage temperature suggests validity of models for arbitrary storage and ambient temperatures. © 2013 Reiter et al.

Cite

CITATION STYLE

APA

Reiter, G., Reiter, U., Wagner, T., Kozma, N., Roland, J., Schöllnast, H., … Lanzer, G. (2013). Thermometry of Red Blood Cell Concentrate: Magnetic Resonance Decoding Warm Up Process. PLoS ONE, 8(2). https://doi.org/10.1371/journal.pone.0057931

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free