Synchronous Generator Excitation System for a Ship Based on Active Disturbance Rejection Control

7Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

To solve synchronous generator oscillations in marine power systems which cannot be effectively suppressed, according to the nonlinearity and time variability of the ship power system, a method of synchronous generator excitation control for a ship based on active disturbance rejection control (ADRC) is proposed. Under different working conditions, three methods are automatic voltage regulator (AVR), automatic voltage regulator with power system stabilizer (PSS), and ADRC methods, which are applied to the two-generator parallel-running excitation system of a ship in simulations. The simulation results show that the excitation control system based on ADRC is faster and has better anti-interference ability and has a better restraining effect on synchronous generator oscillation.

Cite

CITATION STYLE

APA

Wang, R., Liu, X., & Huang, Y. (2021). Synchronous Generator Excitation System for a Ship Based on Active Disturbance Rejection Control. Mathematical Problems in Engineering, 2021. https://doi.org/10.1155/2021/6638370