Abstract
Within-person and methodological variability of a given analyte are important elements in determining whether an individual has altered concentrations of that analyte. We report the short-term (1 month) within- person, between-person, and methodological variability of plasma homocysteine in 20 healthy participants from whom samples were drawn weekly for 4 weeks. The short-term between-person variance was high, whereas within-person and methodological variances were relatively very low, giving a high reliability coefficient (R) for homocysteine (R = 0.94). The long-term (30 months) reliability coefficient was 0.65, but was greatly influenced by an outlier (R = 0.82 with the outlier excluded). The data suggest that an individual's plasma homocysteine concentration is relatively constant over at least 1 month, and a single measurement characterizes the average concentration reasonably well.
Author supplied keywords
Cite
CITATION STYLE
Garg, U. C., Zheng, Z. J., Folsom, A. R., Moyer, Y. S., Tsai, M. Y., McGovern, P., & Eckfeldt, J. H. (1997). Short-term and long-term variability of plasma homocysteine measurement. Clinical Chemistry, 43(1), 141–145. https://doi.org/10.1093/clinchem/43.1.141