Abstract
The quality of treatment delivery as prescribed in radiotherapy is exceptionally important. One element that helps provide quality assurance is the ability to carry out time-resolved radiotherapy dose measurements. Reports on doped silica optical fibers scintillators using radioluminescence (RL) based radiotherapy dosimetry have indicated merits, especially regarding robustness, versa-tility, wide dynamic range, and high spatial resolution. Topping the list is the ability to provide time-resolved measurements, alluding to pulse-by-pulse dosimetry. For effective time-resolved dose measurements, high temporal resolution is enabled by high-speed electronics and scintillator material offering sufficiently fast rise and decay time. In the present work, we examine the influence of Ge doping on the RL response of Ge-doped silica optical fiber scintillators. We particularly look at the size of the Ge-doped core relative to the fiber diameter, and its associated effects as it is ad-justed from single-mode fiber geometry to a large core-to-cladding ratio structure. The primary ob-jective is to produce a structure that facilitates short decay times with a sufficiently large yield for time-resolved dosimetry. RL characterization was carried out using a high-energy clinical X-ray beam (6 MV), delivered by an Elekta Synergy linear accelerator located at the Advanced Medical and Dental Institute, Universiti Sains Malaysia (USM). The Ge-doped silica optical fiber scintillator samples, fabricated using chemical vapor deposition methods, comprised of large core and small core optical fiber scintillators with high and low core-to-cladding ratios, respectively. Accordingly, these samples having different Ge-dopant contents offer distinct numbers of defects in the amor-phous silica network. Responses were recorded for six dose-rates (between 35 MU/min and 590 MU/min), using a photomultiplier tube setup with the photon-counting circuit capable of gating time as small as 1 μs. The samples showed linear RL response, with differing memory and afterglow effects depending on its geometry. Samples with a large core-to-cladding ratio showed a relatively short decay time (<1 ms). The results suggest a contribution of Ge-doping in affecting the triplet states of the SiO2 matrix, thereby reducing phosphorescence effects. This is a desirable feature of scintillating glass materials that enables avoiding the pulse pile-up effect, especially in high dose-rate applications. These results demonstrate the potential of Ge-doped optical-fiber scintillators, with a large core-to-cladding ratio for use in time-resolved radiation dosimetry.
Author supplied keywords
Cite
CITATION STYLE
Tarif, Z. H., Oresegun, A., Abubakar, A., Basaif, A., Zin, H. M., Choo, K. Y., … Bradley, D. A. (2022). Time-Resolved Radioluminescence Dosimetry Applications and the Influence of Ge Dopants In Silica Optical Fiber Scintillators. Quantum Beam Science, 6(2). https://doi.org/10.3390/qubs6020015
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.