Injection of low and iso-osmolar contrast medium decreases oxygen tension in the renal medulla

131Citations
Citations of this article
31Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Injection of low and iso-osmolar contrast medium decreases oxygen tension in the renal medulla. The oxygen tension (PO2) in the renal cortex and outer renal medulla in 26 rats was studied by use of oxygen microelectrodes before and after injection of x-ray contrast media (CM). The CM, iopromide, ioxaglate and iotrolan were administrated intravenously in iodine equivalent doses (1,600 mg iodine/kg body wt). Ringer's solution was used as the control. In the outer medulla, all three CM induced a decrease in PO2: iopromide (N = 6) from 30 ± 3 to 18 ± 4 mm Hg; ioxaglate (N = 7) from 32 ± 6 to 15 ± 4 mm Hg; and iotrolan (N = 6) from 36 ± 3 to 14 ± 4 mm Hg. All these decreases were significant. After the injection of Ringer's (N = 7) there was an increase from 34 ± 3 to 35 ± 3 mm Hg. In the cortex a slight decrease was noted after injection of CM, but this was significant only after injection of iotrolan. All tested contrast media decrease PO2 in the outer renal medulla, which may partly explain contrast medium-induced acute renal failure.

Cite

CITATION STYLE

APA

Liss, P., Nygren, A., Erikson, U., & Ulfendahl, H. R. (1998). Injection of low and iso-osmolar contrast medium decreases oxygen tension in the renal medulla. Kidney International, 53(3), 698–702. https://doi.org/10.1046/j.1523-1755.1998.00811.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free