Performance Investigation of a Chimney-Dependent Solar Crop Dryer for Different Inlet Areas with a Fixed Outlet Area

  • Afriyie J
  • Bart-Plange A
N/ACitations
Citations of this article
24Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The paper describes the performance of a direct-mode solar crop dryer with a solar chimney. Tests were performed for three differently inclined drying-chamber roofs, each with three inlet areas for a given exit area. Cassava was used as the test crop. The results show that the increase in the inlet area for a given exit area can improve the ventilation in the dryer. However, this does not necessarily improve the drying performance of the direct-mode dryer. A wide inlet area for a given exit area can only improve the drying performance of the direct-mode dryer in a geographical location of low relative humidity. It is therefore not advisable to just copy the design of a direct-mode dryer from one location to another without regard to the ambient relative humidity. The designer and builder of the dryer must consider the relative humidity as a prime factor in the design and construction of direct-mode dryers, which are highly sensitive to the ambient relative humidity.

Cite

CITATION STYLE

APA

Afriyie, J. K., & Bart-Plange, A. (2012). Performance Investigation of a Chimney-Dependent Solar Crop Dryer for Different Inlet Areas with a Fixed Outlet Area. ISRN Renewable Energy, 2012, 1–9. https://doi.org/10.5402/2012/194359

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free