Abstract
Introduction Sternum is a flat bone composed of three parts: manubrium superiorly, xiphoid process inferiorly and the body in between (Selthofer et al. 2006). Manubrio- Sternal Joint (MSJ), also known as Louis' Angle, is a synarthrosis joint. Manubrium and sternal body intersect with an angle of 165degree to 175degree between their posterior faces (intra-thoracic faces, Carrier et al. 2007). MSJ has implications in rheumatoid diseases and traumatic injuries. The potential MSJ degrees of freedom and range of motion during breathing and their relationships with ventilatory disease management stay controversial. Recently, measurements of sternal angle on 12 asymptomatic subjects' retrospective codified spiral- CT data (Beyer et al. 2017) showed MSJ variations. Subjects were on a supine position and conventional spirometry was added to monitor three states: Total Lung Capacity (TLC), Middle of Inspiratory Capacity (MIC) and Functional Residual Capacity (FRC). MSJ variations mean value from TLC to FRC was 4.4degree +/- 2.7degree. The main limitation of this study is the invasive use of scanner that uses ionising rays. Opto-Electronic Plethysmography (OEP) is a new non-invasive method of chest wall volume assessment based on optical computation of three-dimensional coordinates of markers fixed on the subjects' trunk. OEP can be performed in any position (prone, supine, standing, sitting) without mouthpiece nor nose clip. OEP has been validated as an alternative to conventional spirometry. Difference between chest wall volume measured with OEP and spirometry was <1% according to Cala et al. OEP technique is suitable for acute functional respiratory examination. In the sitting position without backrest, a set of 86 markers is used to calculate total volume of the trunk. Six of these markers placed on different parts of the sternum can be used to determine MSJ displacement. The aim of the present study is to provide a computational method based on OEP in order to quantify MSJ mobility associated with breath. 2. Methods OEP is performed on three sportive males (age = 23 +/- 0.5 years old, height = 1.84 +/- 0.05 m, mass = 70 +/- 2.5 kg) who are asymptomatic subjects (S1, S2, S3). 3D position of external markers is recorded by 8 infrared emitting cameras (Vicon system, 100 Hz). Subjects are in a sitting position without backrest and are asked to perform five vital capacity manoeuvres. Total volume of the trunk was computed using variation of markers 3D position and the Gauss-Ostrogradsky Theorem (Cala et al. 1996; Aliverti et al. 2000) Subtraction of the minimal volume (FRC) to the total volume gives the signal V(t) which corresponds to the lungs' air flow. Three markers are used to determine manubrium orientation in space: two placed on the median axis of the body at the upper extremity of manubrium (Mid1) and at the Louis' Angle (Mid2), and one placed on the right first rib anterior extremity beneath clavicula (RA1). The same arrangement is used to determine the sternum orientation: two median markers at Louis' Angle (Mid2) and lower extremity of the sternum body (Mid3) and one lateral on the second rib costal cartilage (RA2). Median vectors (Mid1-Mid2 and Mid2-Mid3) are used as Z-axis. Cross product is used to generate two direct orthonormal vector fields: ( Xm, Ym, Zm) attached to the manubrium orientation in space and (Xs , Ys , Zs ) attached to the sternum orientation in space. X-axis points to the right and Y-axis points forward. Vector field attached to the sternum was considered as a reference and the vector field attached to the manubrium was mobile. Vector fields are linked by rotation matrix R:* The rotation matrix calculation with Newton-Euler method is composed of three successive rotations: rotation around Xm, then around Ym and finally around Zm: The resultant cardan angles are: hx (flexion/extension), hy (side bending) and hz (left and right rotation). Experimental error of land mark position including motion of soft tissue was calculated with two orthonormal direct vector fields attached on coxal bones. Mean experimental error was 1,20degree on hx. V(t), hx(t), hy(t), and hz(t) are analysed both on time domain using cross-correlation coefficient r and on frequency domain using a Fast Fourier Transform algorithm in order to differentiate noise and MSJ signal. 3. Results and discussion hx(t) and V(t) signals present for each subject correlation on time domain (Figure 1). Cross-correlation coefficients are greater than 0,8 with a phase signal equal to 0ms (Table 1). Signals have similar curves in the frequency domain (Figure 2). hx standard deviation had a mean value of 5.76degree (Table 1). This indicates significant flexion and extension of the MSJ during breathing. Comparisons of hy(t) and hz(t) to V(t) show uncorrelated curves on both time and frequency domain. It indicates that variations are not related to breath and are made of noise. During inspiration hx value increases. Manubrium rotates counter clockwise around X-axis, which corresponds to a backward inclination: Louis' angle becomes more prominent. The opposite occurs during expiration: hx value decreases and the Louis' angle becomes flatter. This result is in accordance with Beyer et al. conclusions. 4. Conclusion This study shows that it is possible to measure MSJ mobility during breathing subject using non-invasive OEP method (Kaneko and Horie 2012). OEP assessment provides non ionising ray, reduces subject's stress associated with conventional spirometry monitoring (nose clip and mouthpiece) and better explains the dynamic coordination (function of time) between MSJ and breath. The feasibility of this measurement is a first step for further studies that will concentrate on the possible link between that joint and pathologies like scoliosis, asthma or COPD. This could also provide new focusses about the influence of manual therapies on breath functions. Acknowledgments Authors would like to thank Roger, Christophe and Olivier Caporossi, Serge Pin, Laurent Stubbe and Jeanine Sanchez, ESO - Paris and the University of Reims-Champagne- Ardennes management. (Figure Presented).
Cite
CITATION STYLE
Gaillard, L., Debraux, L., & Houel, N. (2019). Manubrio-sternal joint mobility during forced ventilation using non-invasive opto-electronic plethysmography: cases studies. Computer Methods in Biomechanics and Biomedical Engineering, 22(sup1), S411–S412. https://doi.org/10.1080/10255842.2020.1714963
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.