Abstract
The complexity of biologic tissues, with multiple compartments each with its own diffusion and relaxation properties, requires complex formalisms to model water signal in most magnetic resonance imaging or magnetic resonance spectroscopy experiments. In this article, we describe a magnetic susceptibility-induced shift in the resonance frequency of extracellular water by the introduction of a gadolinium contrast agent to medium perfusing a hollow fiber bioreactor. The frequency shift of the extracellular water (+185 Hz at 9.4 T) uncovers the intracellular water and allows direct measurement of motional and relaxation properties of the intracellular space. The proposed method provides a unique tool for understanding the mechanisms underlining diffusion and relaxation in the intracellular space. © 2005 Wiley-Liss, Inc.
Author supplied keywords
Cite
CITATION STYLE
Galons, J. P., Lope-Piedrafita, S., Divijak, J. L., Corum, C., Gillies, R. J., & Trouard, T. P. (2005). Uncovering of intracellular water in cultured cells. Magnetic Resonance in Medicine, 54(1), 79–86. https://doi.org/10.1002/mrm.20565