Effect of different occlusal materials on peri‑implant stress distribution with different osseointegration condition: A finite element analysis

3Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Aim: Studies have not been done to evaluate the peri-implant stress exerted by materials(like PEEK and resin matrix ceramics) in different osseointegration conditions. To investigate the effect of different occlusal materials on peri-implant stress distribution with different osseointegration condition using finite element analysis. Settings and Design: Eighteen different 3D FEA models of implant fixed with abutment were created involving 6 different occlusal materials (Heat cured temporary acrylic resin (PMMA), Bis-GMA, PEEK, Lithium disilicate, Resin matrix ceramics and translucent Zirconia) and different osseointegrated conditions (50%, 75%, 100%). Materials and Methods: Models were subjected to loading vertically and obliquely followed by evaluation of stress distribution. Statistical Analysis Used: The results of the simulation obtained were analysed in terms of Von mises, maximum principal and minimal principal stresses using descriptive stastistics. Results: PMMA (40.14 MPa on vertical loading and 66 MPa on oblique loading) resulted in the highest stresses and lithium disilicate (24 MPa on vertical loading and 52.40 MPa on oblique loading) resulted in least stresses among all the crown materials. Upon oblique loading, von Mises stress increases except for translucent zirconia and lithium disilicate (52.444 MPa on 50%, 47.733 MPa on 75%, and 43.973 MPa on 100% osseointegration). Minimal principal stress values decreased with increase in osseointegration upon oblique loading for PMMA, BisGMA, and PEEK. Conclusion: Translucent zirconia and lithium disilicate offer a better stress transmission. Minimal principal stress values of PEEK and BisGMA decreased with increasing osseointegration.

Cite

CITATION STYLE

APA

Dhanasekaran, T., Andonissamy, L., Abdullah, F., & Paramasivam, Y. S. (2024). Effect of different occlusal materials on peri‑implant stress distribution with different osseointegration condition: A finite element analysis. Journal of Indian Prosthodontic Society, 24(3), 292–299. https://doi.org/10.4103/jips.jips_424_23

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free