Simultaneous serodetection of 10 highly prevalent mouse infectious pathogens in a single reaction by multiplex analysis

51Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Under current practices of mouse colony maintenance, sera from mice are analyzed for antibodies against several widespread infectious pathogens by conventional immunoassays, generally enzyme-linked immunosorbent assay (ELISA). To test for multiple agents, these methods consume large volumes of mouse serum and are laborious and time-consuming. More efficient immunoassays, using small amounts of sample, are therefore needed. Accordingly, we have developed a novel multiplex diagnostic system that employs fluorescent microbeads, coated with purified antigens, for simultaneous serodetection of 10 mouse infectious agents. Individually identifiable, fluorescent microbeads were coated with antigens from Sendai virus, mouse hepatitis virus, Theiler's mouse encephalomyelitis virus/GDVII strain, mouse minute virus, mouse cytomegalovirus, respiratory enteric orphan virus (Reo-3 virus), mouse parvovirus, calf rotavirus for epizootic diarrhea virus of infant mice, vaccinia virus for ectromelia virus, and Mycoplasma pulmonis. Standard sera, singly positive for antibodies to individual infectious agents, were generated by inoculation of BALB/6j and C57BL/6j mice. Sera from these experimentally infected mice, as well as sera from naturally infected mice, were analyzed using a mixture of microbeads coated with antigens of the 10 infectious agents listed above. Results demonstrated that the multiplex assay was at least as sensitive and specific as ELISA for serodetection. Importantly, the multiplex assay required only 1 microliter of serum for simultaneous serodetection of the 10 mouse infectious agents in one reaction vessel. Thus, this multiplex microbead assay is a reliable, efficient, and cost-effective diagnostic modality that will impact serosurveillance of mice used in research. Copyright © 2005, American Society for Microbiology. All Rights Reserved.

Cite

CITATION STYLE

APA

Khan, I. H., Kendall, L. V., Ziman, M., Wong, S., Mendoza, S., Fahey, J., … Luciw, P. A. (2005). Simultaneous serodetection of 10 highly prevalent mouse infectious pathogens in a single reaction by multiplex analysis. Clinical and Diagnostic Laboratory Immunology, 12(4), 513–519. https://doi.org/10.1128/CDLI.12.4.513-519.2005

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free