Advantages of combined technetium-99m-sestamibi scintigraphy and high-resolution ultrasonography in parathyroid localization: Comparative study in 91 patients with primary hyperparathyroidism

152Citations
Citations of this article
39Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: To evaluate the usefulness of the combination of 99mTc-sestamibi/99mTc-pertechnetate subtraction scintigraphy (SS) and high-resolution neck ultrasonography (US) in patients with primary hyperparathyroidism (pHPT) undergoing parathyroidectomy. Design and Methods: Ninety-one patients with proved pHPT were studied, excluding patients with persistent or recurrent disease. There were 65 (71.4%) women and 26 (28.6%) men, with a median age of 59 years (range 18-78 years). All patients underwent both SS and US prior to surgery, and the results were compared with operative and histological findings. The intraoperative quick-parathyroid hormone assay was available for 52 (57.1%) patients. When multiglandular disease was found, both SS and US were considered truly positive only when at least two enlarged parathyroid (PT) glands had been localized. Results: Eighty-three (91.2%) solitary PT adenomas and three (3.3%) carcinomas were found. Moreover, two (2.2%) patients had a double adenoma and three (3.3%) patients had diffuse PT hyperplasia. The overall sensitivity of combined SS + US was 94.5% (86.8% and 80.4% for SS and US respectively). There was a significant (P < 0.05, Student's t-test) difference in size between the PT glands correctly identified and undetected by SS, whereas the site of the removed PT tumors significantly (P < 0.05, Fisher exact test) influenced only the US sensitivity. Conclusions: When the preoperative localization of the PT glands is chosen, the combination of SS and US represents a reliable noninvasive localization technique and should be considered for use in each patient with pHPT undergoing surgery.

Cite

CITATION STYLE

APA

Lumachi, F., Zucchetta, P., Marzola, M. C., Boccagni, P., Angelini, F., Bui, F., … Favia, G. (2000). Advantages of combined technetium-99m-sestamibi scintigraphy and high-resolution ultrasonography in parathyroid localization: Comparative study in 91 patients with primary hyperparathyroidism. European Journal of Endocrinology, 143(6), 755–760. https://doi.org/10.1530/eje.0.1430755

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free