Impact of Age on Subcutaneous Implantable Cardioverter-Defibrillator in a Large Patient Cohort: Mid-Term Follow-Up

4Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an accepted alternative to transvenous (TV) ICD to provide defibrillation therapy to treat life-threatening ventricular tachyarrhythmias in high-risk patients. S-ICD outcomes by age group have not been reported. Objectives: In this study, the authors sought to report S-ICD outcomes in different age groups in a multicenter S-ICD post-approval study (PAS) involving the largest cohort of patients ever reported. Methods: Patients were prospectively enrolled in the S-ICD PAS and stratified based on age: young, aged 15-34 years; adult, aged 35-69 years; and elderly, aged ≥70 years. Patient characteristics and clinical outcomes through 3 years of follow up after implantation were compared. Results: The S-ICD PAS enrolled 1,637 patients. Elderly patients were more likely to receive an S-ICD as a replacement of a TV-ICD (15.1% elderly vs 12.3% adult vs 7.4% young). Secondary prevention indication decreased with age (32.7% young vs 22.2% adult vs 20.5% elderly). Mortality rate was significantly higher in the elderly group (24.0% elderly vs 13.0% adult vs 7.4% young; P < 0.0001), whereas the complication rate did not differ significantly (12.3% young vs 11.3% adult vs 8.1% elderly). Rates of appropriate shock (12.7% young vs 13.0% adult vs 13.8% elderly) and inappropriate shock (7.8% young vs 9.1% adult vs 8.8% elderly) rates did not differ between groups (P = 0.96 and P = 0.98, respectively). Conclusions: Implant complications and appropriate and inappropriate shock rates were similar among age groups. S-ICD for secondary prevention was more common in the young group. Replacing a TV-ICD for an S-ICD increases with age. (S-ICD System Post-Approval Study; NCT01736618)

Cite

CITATION STYLE

APA

Weiss, R., Knight, B. P., El-Chami, M., Aasbo, J., Hanon, S., Sadhu, A., … Gold, M. (2023). Impact of Age on Subcutaneous Implantable Cardioverter-Defibrillator in a Large Patient Cohort: Mid-Term Follow-Up. JACC: Clinical Electrophysiology, 9(10), 2132–2145. https://doi.org/10.1016/j.jacep.2023.06.013

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free