Abstract
Background. Infection and epidural abscess are important complications of epidural analgesia. Difficult insertion may be associated with an increased risk of bacterial contamination of the epidural needle or catheter. Methods. Bacterial contamination of epidural needles and trocars after difficult epidural insertion, difined as two or more skin passes, was assessed in 38 obstetric and ten gynaecological patients. Results. There was no bacterial growth on any of the 48 epidural needles or trocars despite 0the mean (range) insertion time being 20 (10-30) min and the number of insertion attempts being 3 (2-4). Conclusion. Difficult epidural insertion is not associated with an increased risk of needle contamination and is therefore an unlikely source of epidural infection.
Author supplied keywords
Cite
CITATION STYLE
Orlikowski, C., Majedi, P. M., & Keil, A. D. (2002). Bacterial contamination of epidural needles after multiple skin passes. British Journal of Anaesthesia, 89(6), 922–924. https://doi.org/10.1093/bja/aef285