Hypovolemia-induced hypotension may lead to an aortic diameter decrease in patients with a ruptured abdominal aortic aneurysm (rAAA). This study investigates the changes in supra-and infra-renal aortic neck diameters before and after endovascular aortic aneurysm repair (EVAR) for rAAA and the possible association with endograft apposition. A retrospective cohort study was conducted including 74 patients treated between 2010 and 2019 in two large European vascular centers. Outer-to-outer wall diameters were measured at +40, +10, 0, −10, and −20 mm relative to the lowest renal artery baseline on the last pre-and first post-EVAR computed tomography angiography (CTA) scan in a vascular workstation. Endograft apposition was determined on the first post-EVAR CTA scan. The post-operative diameter was significantly (p < 0.001) larger than the preoperative diameter at all aortic levels. The aortic diameter at +40 mm (supra-renal) and −10 mm (infra-renal) increased by 6.2 ± 7.3% and 12.6 ± 9.8%, respectively. The aortic diameter at +40 mm increased significantly more in patients with low preoperative systolic blood pressure (<90 mmHg; p = 0.005). A shorter apposition length was associated with a higher aortic diameter increase (R = −0.255; p = 0.032). Hypovolemic-induced hypotension results in a significant decrease in the aortic diameter in patients with an rAAA, which should be taken into account when oversizing the endograft.
CITATION STYLE
van der Riet, C., Schuurmann, R. C. L., Karelis, A., Suludere, M. A., van Harten, M. J., Sonesson, B., … Dijkstra, M. L. (2022). Supra-and Infra-Renal Aortic Neck Diameter Increase after Endovascular Repair of a Ruptured Abdominal Aortic Aneurysm. Journal of Clinical Medicine, 11(5). https://doi.org/10.3390/jcm11051203
Mendeley helps you to discover research relevant for your work.