Sub-Å STEM Resolution From 30-300kV

  • Bischoff M
  • Niestadt M
  • Altin V
  • et al.
N/ACitations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Interest in low-kV STEM imaging has been fueled by increasing research on novel materials such as carbon-based nano-materials and other low-dimensional materials. Atomic resolution imaging of these classes of materials is seriously affected by radiation damage and weak signals leading to low contrast in the images. Therefore high contrast, beam-damage-free imaging can often only be achieved at low to very low accelerating voltages. Imaging below the critical knock-on damage threshold is the key to success and for some materials this can be well below 60kV. To maintain optical performance at lower voltages, higher opening angles of the probe have to be used (diffraction limit). Hence the higher order aberrations of the optics, which increase dramatically with higher opening angles and lower voltages, need to be measured and corrected with high precision. Monochromation of the electron beam has proven to be an effective way to reduce chromatic blurring and the Thermo Fisher monochromator-although not specifically developed for imaging-has demonstrated to be a good fit for the purpose of low-kV imaging. The probe corrector can potentially eliminate, or at least significantly reduce, the resolution-limiting aberrations even at low accelerating voltages but some limitations still remain. The corrector must be able to correct up to the 5 th order aberrations over the entire high tension range of the tool (300-30kV) so that optimum imaging performance is achieved for the high tension selected to best suit the material being investigated. Additionally, for correction, the biggest remaining challenge is measuring the aberrations with sufficient confidence to come to reproducible results during daily operation. We will discuss in this presentation how to achieve optimized imaging performance for a wide high tension range, excellent reproducibility of operation and ultimate precision in atomic imaging. With all aberrations corrected, results like the example shown in figure 1 and figure 2 are routinely achievable on a system with full high tension flexibility.

Cite

CITATION STYLE

APA

Bischoff, M., Niestadt, M., Altin, V., Henstra, A., Tiemeijer, P., Freitag, B., … Van Cappellen, E. (2018). Sub-Å STEM Resolution From 30-300kV. Microscopy and Microanalysis, 24(S1), 1134–1135. https://doi.org/10.1017/s1431927618006153

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free