Current Surgical Risk Scores Overestimate Risk in Minimally Invasive Aortic Valve Replacement

14Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: Risk-scoring systems for surgical aortic valve replacement (AVR) were largely derived from sternotomy cases. We evaluated the accuracy of current risk scores in predicting outcomes after minimally invasive AVR (mini-AVR). Because transcatheter AVR (TAVR) is being considered for use in low-risk patients with aortic stenosis, accurate mini-AVR risk assessment is necessary. Methods: We reviewed 1,018 consecutive isolated mini-AVR cases (2009 to 2015). After excluding patients with Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) scores ≥4, we calculated each patient’s European System for Cardiac Operative Risk Evaluation (EuroSCORE) II, TAVR Risk Score (TAVR-RS), and age, creatinine, and ejection fraction score (ACEF). We compared all 4 scores’ accuracy in predicting mini-AVR 30-day mortality by computing each score’s observed-to-expected mortality ratio (O:E). Area under the receiver operating characteristic (ROC) curves tested discrimination, and the Hosmer–Lemeshow goodness-of-fit tested calibration. Results: Among 941 patients (mean age, 72 ± 12 years), 6 deaths occurred within 30 days (actual mortality rate, 0.6%). All 4 scoring systems overpredicted expected mortality after mini-AVR: ACEF (1.4%), EuroSCORE II (1.9%), STS-PROM (2.0%), and TAVR-RS (2.1%). STS-PROM best estimated risk for patients with STS-PROM scores 0 to <1 (0.6 O:E), ACEF for patients with STS-PROM scores 2 to <3 (0.6 O:E), and TAVR-RS for patients with STS-PROM scores 3 to <4 (0.7 O:E). ROC curves showed only fair discrimination and calibration across all risk scores. Conclusions: In low-risk patients who underwent mini-AVR, current surgical scoring systems overpredicted mortality 2-to-3-fold. Alternative dedicated scoring systems for mini-AVR are needed for more accurate outcomes assessment.

Cite

CITATION STYLE

APA

Alnajar, A., Chatterjee, S., Chou, B. P., Khabsa, M., Rippstein, M., Lee, V. V., … Lamelas, J. (2021). Current Surgical Risk Scores Overestimate Risk in Minimally Invasive Aortic Valve Replacement. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 16(1), 43–51. https://doi.org/10.1177/1556984520971775

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free