Automatic couch position calculation using eclipse scripting for external beam radiotherapy

4Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: The treatment couch position of a patient in external beam radiation therapy (EBRT) is usually acquired during initial treatment setup. This procedure has shown potential failure modes leading to near misses and adverse events in radiation treatment. This study aims to develop a method to automatically determine the couch position before setting up a patient for initial treatment. Methods: The Qfix couch-tops (kVue and DoseMax) have embedded reference marks (BBs) indicating its index levels and couch centerline. With the ESAPI, a C# script was programmed to automatically find the couch-top and embedded BBs in the planning CT and derive the treatment couch position according to treatment isocenter of a plan. Couch positions of EBRT plans with the kVue couch-top and SBRT plans using the DoseMax were calculated using the script. The calculation was evaluated by comparing calculated positions with couch coordinates captured during the initial treatment setup after image guidance. The calculations were further compared with daily treatment couch positions post image-guided adjustment for each treatment fraction. Results: For plans using the kVue couch-top for various treatment sites, the median (5–95 percentiles) differences between calculated and captured couch positions were 0.1 (−0.2 – 0.9), 0.5 (−1.1–2.0), 0.10 (−1.3–1.3) cm in the vertical, longitudinal, and lateral direction respectively. For the DoseMax couch-top, the median differences were 0.1 (−0.2–0.7), 0.2 (−0.3–1.1), and 0.2 (−0.7–0.9) cm in respective direction. The calculated positions were within 1 and 2 cm from the mean fraction positions for 95% patients on DoseMax and kVue couch-top respectively. Conclusions: A method that automatically and accurately calculates treatment couch position from simulation CT was implemented in Varian Eclipse for Qfix couch-tops. This technique increases the efficiency of patient setup and enhances patient safety by reducing the risks of positioning errors.

Cite

CITATION STYLE

APA

Wang, H., Rea, A., Rudek, B., Chen, T., McCarthy, A., & Barbee, D. (2021). Automatic couch position calculation using eclipse scripting for external beam radiotherapy. Journal of Applied Clinical Medical Physics, 22(2), 77–84. https://doi.org/10.1002/acm2.13159

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free