Urine assay for tenofovir to monitor adherence in real time to tenofovir disoproxil fumarate/emtricitabine as pre-exposure prophylaxis

59Citations
Citations of this article
78Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objectives: Tenofovir disoproxil fumarate/emtricitabine (TDF/FTC) is approved for pre-exposure prophylaxis (PrEP) against HIV infection. Adherence is critical for the success of PrEP, but current adherence measurements are inadequate for real-time adherence monitoring. We developed and validated a urine assay to measure tenofovir (TFV) to objectively monitor adherence to PrEP. Methods: We developed a urine assay using high-performance liquid chromatography coupled to tandem mass spectrometry with high sensitivity/specificity for TFV that allowed us to determine TFV concentrations in log10 categories between 0 and 10 000 ng/mL. We validated the assay in three cohorts: (1) HIV-positive subjects with undetectable viral loads on a TDF/FTC-based regimen, (2) healthy HIV-negative subjects who received a single dose of TDF/FTC, and (3) HIV-negative subjects receiving daily TDF/FTC as PrEP for 24 weeks. Results: The urine assay detected TFV with greater sensitivity than plasma-based measures and with a window of measurements within 7 days of the last TDF/FTC dose. Based on the urine log-linear clearance after the last dose and its concordance with all detectable plasma levels, a urine TFV concentration > 1000 ng/mL was identified as highly predictive of the presence of TFV in plasma at > 10 ng/mL. The urine assay was able to distinguish high and low adherence patterns within the last 48 h (> 1000 ng/mL versus 10–1000 ng/mL), as well as nonadherence (< 10 ng/mL) extended over at least 1 week prior to measurement. Conclusions: We provide proof of concept that a semiquantitative urine assay measuring levels of TFV could be further developed into a point-of-care test and be a useful tool to monitor adherence to PrEP.

Cite

CITATION STYLE

APA

Koenig, H. C., Mounzer, K., Daughtridge, G. W., Sloan, C. E., Lalley-Chareczko, L., Moorthy, G. S., … Tebas, P. (2017). Urine assay for tenofovir to monitor adherence in real time to tenofovir disoproxil fumarate/emtricitabine as pre-exposure prophylaxis. HIV Medicine, 18(6), 412–418. https://doi.org/10.1111/hiv.12518

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free