Double cycling with breath-stacking during partial support ventilation in ARDS: Just a feature of natural variability?

3Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Double cycling with breath-stacking (DC/BS) during controlled mechanical ventilation is considered potentially injurious, reflecting a high respiratory drive. During partial ventilatory support, its occurrence might be attributable to physiological variability of breathing patterns, reflecting the response of the mode without carrying specific risks. Methods: This secondary analysis of a crossover study evaluated DC/BS events in hypoxemic patients resuming spontaneous breathing in cross-over under neurally adjusted ventilatory assist (NAVA), proportional assist ventilation (PAV +), and pressure support ventilation (PSV). DC/BS was defined as two inspiratory cycles with incomplete exhalation. Measurements included electrical impedance signal, airway pressure, esophageal and gastric pressures, and flow. Breathing variability, dynamic compliance (CLdyn), and end-expiratory lung impedance (EELI) were analyzed. Results: Twenty patients under assisted breathing, with a median of 9 [5–14] days on mechanical ventilation, were included. DC/BS was attributed to either a single (42%) or two apparent consecutive inspiratory efforts (58%). The median [IQR] incidence of DC/BS was low: 0.6 [0.1–2.6] % in NAVA, 0.0 [0.0–0.4] % in PAV +, and 0.1 [0.0–0.4] % in PSV (p = 0.06). DC/BS events were associated with patient’s coefficient of variability for tidal volume (p = 0.014) and respiratory rate (p = 0.011). DC/BS breaths exhibited higher tidal volume, muscular pressure and regional stretch compared to regular breaths. Post-DC/BS cycles frequently exhibited improved EELI and CLdyn, with no evidence of expiratory muscle activation in 63% of cases. Conclusions: DC/BS events during partial ventilatory support were infrequent and linked to breathing variability. Their frequency and physiological effects on lung compliance and EELI resemble spontaneous sighs and may not be considered a priori as harmful.

Cite

CITATION STYLE

APA

Brito, R., Morais, C. C. A., Arellano, D. H., Gajardo, A. I. J., Bruhn, A., Brochard, L. J., … Cornejo, R. A. (2025). Double cycling with breath-stacking during partial support ventilation in ARDS: Just a feature of natural variability? Critical Care, 29(1). https://doi.org/10.1186/s13054-025-05260-7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free