Abstract
Commercial Inconel 600 nickel-chromium alloy was implanted with nitrogen, titanium, chromium, copper with tin (as bronze components) and yttrium ions to doses ranging from 1.6e17 to 3.5e17 cm?2. The aim of this research was to investigate the properties of the modified alloy in the context of its application in foil bearings. The virgin and the treated samples were tribologically tested and examined by Scanning Electron Microscopy, Glow Discharge Mass Spectrometry and Energy Dispersive Spectroscopy. The technological studies were preceded by modelling of concentration values of the introduced elements. The results obtained with the use of ion implantation are discussed. There are two advantages which should be highlighted: good agreement in modelling and experimental results of depth profiles of implanted ions, wear resistance improvement of Inconel 600 surface by implantation of copper and tin ions. The tribological tests indicate that abrasion and corrosion are the predominant mechanisms of surface wear.
Author supplied keywords
Cite
CITATION STYLE
Barlak, M., Chmielewski, M., Werner, Z., Konarski, P., Pietrzak, K., & Strojny-Nędza, A. (2014). Changes of tribological properties of Inconel 600 after ion implantation process. Bulletin of the Polish Academy of Sciences: Technical Sciences, 62(4), 827–833. https://doi.org/10.2478/bpasts-2014-0091