Variation in use of dual-chamber implantable cardioverter-defibrillators: Results from the National Cardiovascular Data Registry

36Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Among patients without an indication for a pacemaker, current evidence is inconclusive whether a dual-chamber implantable cardioverter- defibrillator (ICD) is superior to a single-chamber ICD. The current use of dual-chamber ICDs is not well characterized. Methods: We conducted a cross-sectional study exploring hospital-level variation in the use of dual-chamber ICDs across the United States. Patients receiving a primary prevention ICD from 2006 through 2009 without a documented indication for a pacemaker were included. Multivariate hierarchical logistic regression was used to explore patient, health care provider, and physician factors related to the use of a dual-chamber device. Results: Dual-chamber devices were implanted in 58% of the 87 115 patients without a pacing indication among 1293 hospitals, with hospital rates ranging from 0% in 33 centers to 100% in 109 centers. In multivariate analysis, geographic region was a strong independent predictor of dual-chamber device use, ranging from 36.4% in New England (reference region) to 66.4% in the Pacific region (odds ratio [OR], 5.25; 95% CI, 3.35-8.21). Hospital clustering was assessed using a median OR which was 3.96, meaning that 2 identical patients at different hospitals would have nearly a 4-fold difference in their chance of receiving a dual-chamber ICD. Conclusions: Use of dual-chamber ICDs for the primary prevention of sudden cardiac death among patients without an indication for permanent pacing varies markedly at the hospital level in the United States. This is a clear example of how practice can vary independent of patient factors. ©2012 American Medical Association. All rights reserved.

Cite

CITATION STYLE

APA

Matlock, D. D., Peterson, P. N., Wang, Y., Curtis, J. P., Reynolds, M. R., Varosy, P. D., & Masoudi, F. A. (2012). Variation in use of dual-chamber implantable cardioverter-defibrillators: Results from the National Cardiovascular Data Registry. Archives of Internal Medicine, 172(8), 634–641. https://doi.org/10.1001/archinternmed.2012.394

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free