A highly-sensitive plasma von Willebrand factor ristocetin cofactor (VWF:RCo) activity assay by flow cytometry

44Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Assays of plasma von Willebrand factor (VWF) ristocetin cofactor activity (VWF:RCo) are essential for the laboratory diagnosis of von Willebrand disease (VWD) and for monitoring therapy. However, current manual or automated VWF:RCo assay methods have relatively poor operating characteristics. Our goal was to develop and validate a simple, accurate, specific and sensitive platelet-based VWF:RCo assay. Methods: Using green or red fluorochrome-labeled, fixed normal platelets and normal or patient plasma, ristocetin-dependent and VWF-mediated platelet aggregation was detected by flow cytometry. VWF:RCo activity was assayed as the number of double-positive events (green and red) among all green or red events, relative to the calibrator plasma signal (6-150% or IUdL-1), and reported as percent or IUdL-1. We tested plasma samples from normal donors (n = 51) and known VWD patients (type 1, n = 16; type 2, n = 17) based on clinical history, levels of plasma VWF antigen (VWF:Ag), VWF:RCo activity (manual platelet aggregometry/agglutination assay), factor (F) VIII activity and VWF multimer analysis. Results: For normal donors and type 1 VWD patients, VWF:RCo activity by flow cytometry vs. manual platelet aggregation correlated closely (R2 = 0.74), and VWF:RCo/VWF:Ag ratios did not differ significantly. In contrast, VWF:RCo/VWF:Ag ratios for type 2 VWD subtypes were significantly lower using VWF:RCo by flow cytometry vs. manual platelet aggregation assay (P < 0.01), especially for type 2A VWD patients. Conclusions: This new flow cytometry-based VWF:RCo assay is simple, accurate, specific and sensitive, particularly for type 2 VWD. © 2007 International Society on Thrombosis and Haemostasis.

Cite

CITATION STYLE

APA

Chen, D., Daigh, C. A., Hendricksen, J. I., Pruthi, R. K., Nichols, W. L., Heit, J. A., & Owen, W. G. (2008). A highly-sensitive plasma von Willebrand factor ristocetin cofactor (VWF:RCo) activity assay by flow cytometry. Journal of Thrombosis and Haemostasis, 6(2), 323–330. https://doi.org/10.1111/j.1538-7836.2008.02845.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free