Esophageal baseline impedance from high-resolution impedance manometry correlates with mean nocturnal baseline impedance from pH-impedance monitoring

9Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Abstract

Background/Aims Esophageal baseline impedance (BI) can be extracted from pH-impedance tracings as mean nocturnal baseline impedance (MNBI), and from high-resolution impedance manometry (HRIM), but it is unknown if values are similar between acquisition methods across HRIM manufacturers. We aim to assess correlations between MNBI and BI from HRIM (BI-HRIM) from 2 HRIM manufacturers in the setting of physiologic acid exposure time (AET). Methods HRIM and pH-impedance monitoring demonstrating physiologic AET (< 4%) off proton pump inhibitors were required. BI-HRIM was extracted as the average from 5 cm and 10 cm above the lower esophageal sphincter. Distal BI-HRIM (DBI-HRIM) was also extracted from the most distal channel (Medtronic studies). MNBI was extracted from 6 channels. Concordance between BI-HRIM across manufacturers with MNBI was analyzed. Results Thirty-six patients met the inclusion criteria (59.6 ± 1.7 years; 22% female; body mass index 30.5 ± 0.7; AET 1.6 ± 0.2%). Although MNBI was similar at all channels (P ≥ 0.18), Diversatek BI-HRIM was lower than Medtronic BI-HRIM (P = 0.003). Overall, BI-HRIM correlated with MNBI at corresponding recording sites, 7 cm and 9 cm (P < 0.05), but not at other sites (P ≥ 0.19). Pearson’s correlations > 0.5 were seen at MNBI at 7 cm for both systems, and at 9 cm for Medtronic. DBI-HRIM correlated with MNBI at 3 cm and 5 cm (P < 0.03), but not at other locations (P > 0.1). Conclusions While numeric differences exist between manufacturers, BI-HRIM correlates with MNBI from corresponding channels in patients with physiologic AET. Comparison with AET elevation is needed to determine correlations between pathologic MNBI with BI-HRIM across manufacturers. The optimal HRIM channels from which BI values should be extracted also warrants further study.

Cite

CITATION STYLE

APA

Horton, A., Sullivan, B., Charles, K., McIntosh, T., Davis, A., Gellad, Z., … Patel, A. (2020). Esophageal baseline impedance from high-resolution impedance manometry correlates with mean nocturnal baseline impedance from pH-impedance monitoring. Journal of Neurogastroenterology and Motility, 26(4), 455–462. https://doi.org/10.5056/jnm19142

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free