Accuracy of Patient-Specific Instruments for Supramalleolar Osteotomies

0Citations
Citations of this article
3Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Supramalleolar osteotomy (SMO) enables deformity correction of the distal tibia, but the procedure remains technically demanding. Patient-specific instruments (PSIs) have the potential to mitigate the technical drawbacks associated with SMO that are performed free-hand, but their accuracy has not been investigated. Therefore, we aimed to perform a pre- vs post-operative comparison to assess the accuracy of PSI in the setting of SMO correction. Methods: Eighteen patients (mean age = 47 ± 13.5 years) who underwent SMO with a PSI were prospectively recruited in a pre-post comparative study design. Inclusion criteria were correction of supramalleolar ankle varus or valgus deformity by a closing wedge SMO. Exclusion criteria consisted of biplanar SMO that required associated free-hand osteotomies. Clinical outcomes were collected by the American Orthopaedic Foot & Ankle Society (AOFAS), European Foot and Ankle Society (EFAS), and visual analogue scale (VAS) scores. Apart from the standard weightbearing radiographs, a weightbearing CT was performed to generate corresponding 3-dimensional (3D) bone models and measure the lateral distal tibia angle (LDTA) as main radiographic parameter. Results: The pre-operative radiographic parameters of the tibia joint alignment in patients with ankle varus (n = 12) deformity (LDTAvar = 96.5° ± 4.5°) and valgus (n = 6) deformity (LDTAvalg = 82.4° ± 2.5°) improved significantly relative to their post-operative equivalents (LDTAvar = 90.2° ± 3.2°); LDTAvalg = 90.9° ± 0.8°; P < .05). The pre-operative clinical outcome scores (AOFAS = 52.7 ± 22.9, EFAS = 15.1° ± 7.91°, VAS = 5 [2-8]) improved significantly relative to their post-operative equivalents (AOFAS = 75.5 ± 19.6; EFAS = 19° ± 7.6°; VAS = 3 [0-8]; P < .05). The mean simulated correction differed from the mean post-operative achieved correction within 1° (mean = 0.4°; range 0.1°-0.8°). Conclusion: This study demonstrated an accurate correction of distal tibia deformities by SMO using PSIs. The achieved post-operative correction differed within the range of 1° from the pre-operatively simulated correction. This indicates that PSIs provide a precise execution of the pre-operative planning. Future studies should assess the added value of performing an SMO with PSI compared with former free-hand techniques towards clinical and radiographical outcomes.

Cite

CITATION STYLE

APA

Bonte, C., Rasschaert, J., L’Herroux, J., Peiffer, M., Krähenbühl, N., Buedts, K., … Burssens, A. (2026). Accuracy of Patient-Specific Instruments for Supramalleolar Osteotomies. Foot and Ankle International. https://doi.org/10.1177/10711007261434977

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free